100 MM.Ø SCHEDULE 40 PVC WASTE ​STACK/SEWER STACK

6759 ​22' - 2"

INDIVIDUAL REAR ​YARD

PVC TRUNKING COVER FOR ​INSULATED REFRIGERANT LINES ​FROM AC CLG #01 UNIT

20 MM.Ø PVC CONDENSATE DRAIN ​PIPE TAPPED TO UTILITY SINK DRAIN

ACCU # 01

100 MM.Ø PVC DOWNSPOUT/ ROOF DRAIN TO BOX DRAIN AT REAR OF PROPERTY

IS

FLUSHED TYPE EXTRACTOR VENT ​DI F F USER S

LANDSCAPED AREA

AC CLG # 01

INSULATED REFRIGERANT PIPES ​INSIDE CEILING

POWER SUPPLY LINE FOR AC ACCU ​INSIDE 12.5MM.Ø PVC CONDUIT PIPE ​INSTALLED IN CEILING

DRYWALL CLADDING OF SANITARY PIPE & PIPE VENT ​PROVIDE ACCESS PANEL/ MECHANISM

LIVING AREA

LAUNDRY

100 MM.Ø PVC VENT PIPE

INSIDE CEILING

EF

EXTRACTOR FAN INSTALLED ​AT CEILING LEVEL

POWDER RM. ​ STORAGE

ISOLATION SWITCH

PROPOSED CLADDING PANELS ​FOR EXPOSED PIPES

INSULATED REFRIGERANT PIPES ONSIDE ​PVC TRUNKING

100MM.Ø S-40 PVC WASTE STACK ​AND VTR

POWER LINE INSIDE 12MM.Ø PVC ​CONDUIT PIPE INSIDE CEILING - TO ​ISOLATOR SWITCH AT ROOFDECK

3988

13' - 1"

2589 ​8' - 6"

6759 ​22' - 2"

3870 ​12' - 8"

INSULATED REFRIGERANT PIPELINE INSIDE CEILING ​AND ATTACHED TO UNDERSIDE OF ROOF DECK SLAB ​AND TAPPED TO ACCU RISER TRUNKING

INSULATED REFRIGERANT PIPELINE INSIDE CEILING ​AND ATTACHED TO UNDERSIDE OF ROOF DECK SLAB ​AND TAPPED TO ACCU RISER TRUNKING

FLUSHED TYPE ​EXTRACTOR VENT ​DIFFUSERS

wc

wb

sh.

100 MM.Ø PVC VENT PIPE INSIDE CEILING

wb

MASTER’S BATH & CLOSET ​GF16

AC CLG # 02

20 MM.Ø CONDENSATE DRAIN ​PIPE TAPPED TO WASH BASIN ​DRAIN PIPE

MASTER’S BEDROOM ​GF17

10870

35' - 8"

MAIN STAIRCASE

PANTRY

EF

wb

wc

1

UP

2

3

4

5

6

7

8

1831

6' - 0"

EXTRACTOR FAN INSTALLED ​AT CEILING LEVEL

sh.

COMMON BATH ​GF14

H A L L

19

MAIN STAIRCASE

18

17

16

15

14

13

UP

12

OPEN SPACE

DINING AREA

EXTRACTOR FAN INSTALLED ​AT CEILING LEVEL

RANGE HOOD

MAIN KITCHEN

WALL TYPE OVEN

& MICROWAVE

EF

100 MM.Ø PVC VENT PIPE OR FLEX TUBE INSIDE CEILING

100 MM.Ø SHEDULE 40 - PVC SEWER/ SOUIL PIPE

50 MM. GREY WATER PIPE @ GRADE LEVEL

LANDSCAPED AREA

LANDSCAPED AREA

FLASE COLUMN IN DRYWALL CLADDING

USING CEMENT BOARDS ON METAL STUDS FRAMING\ ​PROVIDE ACCESS PANEL AT LOWER PORTION

ONE STEP ​ENTRY UP

1635 ​5' - 4"

FRONT YARD

FLUSHED TYPE ​EXTRACTOR VENT ​DIFFUSERS

1524 MM. WIDE CONCRETE SIDEWALK

4704

15' - 5"

BEDROOM−03 ​GF12

BEDROOM−02 ​GF13

CONDENSATE DRAIN ​PIPE FOR ACU CLG#03 ​EMBEDDED IN WALL ​DRAINED TO KITCHEN ​GREY WATER LINE

POWER LINE TO ACCU & ISOLATOR SWITCH ​@ ROOF DECK LEVEL

100 MM.Ø PVC DOWNSPOUT W/ PIPE CLADDING ​COVER USING PRE-PAINTED 20 GA BENDED METAL ​SHEETS

INSULATED REFRIGERANT LINE FROM ​AC CLG#04 TO ROOF DECK ACCU

AC CLG # 04

20 MM. Ø PVC CONDENSATE DRAIN ​PIPE FOR AC CLG#04

INSULATED REFRIGERANT LINE FROM ​AC CLG#03 TO ROOF DECK ACCU

AC CLG # 03

2

M−01

FIRST FLOOR MECHANICAL PLAN

1 : 50

597

1' - 11"

RC WHEEL STOP

5500

18' - 1"

PARKING BAYS

1

2

3

1

M−01

6000 MM. WIDE PAVED DRIVEWAY

GROUND FLOOR MECHANICAL PLAN

1 : 50

6759 ​22' - 2"

75MM.Ø PVC RAINLEADER/DOWNSPOUT

100 MM.Ø PVC WASTE STACK

WEATHERPROOF ISOLATOR SWITCH ​WITH INSULATED POWER LINES INSIDE ​PVC CONDUIT RISER FROM FIRST ​FLOOR ACU UNIT

IS

ROOF PLANTERS

ACCU# 2

20 MM.Ø PVC CONDENSATE DRAIN EMBEDDED TO WALL & DRAINED TO ROOF DECK FULLBORRE

100 MM.Ø PVC WASTE STACK

100 MM. Ø VTR ​W/ VENT CAP

ROOF DRAIN

ROOF DRAIN W/ 75 MM. Ø PVC RAINLEADER

OR DOWNSPOUT UNDER FULLBORRE


INSULATED REFRIGERANT PIPELINE

FROM FIRST FLOOR ACU & INSIDE

PVC TRUNKING TO ACCU

VTR

MAIN STAIRCASE

INSULATED REFRIGERANT PIPELINE ​FROM FIRST FLOOR ACU & INSIDE ​PVC TRUNKING TO ACCU

POWER LINE TO ACCU & ISOLATOR SWITCH ​@ ROOF DECK LEVEL

WEATHERPROOF ISOLATOR SWITCH ​WITH INSULATED POWER LINES INSIDE ​PVC CONDUIT RISER FROM FIRST ​FLOOR ACU UNIT

PVC CONDENSATE DRAIN PIPE

FOR AC CLG#03 EMBEDDED TO WALL ​& DRAINED AT GRADE LEVL

IS

305 ​1' - 0"

ROOF DRAIN W/ 100 MM. Ø PVC ​RAINLEADER/ DOWNSPOUT UNDER ​FULLBORRE

INSULATED REFRIGERANT PIPELINE ​FROM FIRST FLOOR ACU & INSIDE ​PVC TRUNKING TO ACCU

ACCU# 3

20 MM.Ø PVC CONDENSATE DRAIN EMBEDDED TO WALL DRAINED TO FULLBORRE

3

M−01

ROOF DECK MECHANICAL PLAN

1 : 50

IS

ACCU# 4

305 ​1' - 0"

1691

5' - 7"

3456

11' - 4"

LEGEND:

AC CLG # 01

INDOOR AC INVERTER UNIT

ACCU#01

OUTDOOR AIRCON CONDENSING ​UNIT FLOOR OR WALL MOUNTED

EF

EXTRACTOR FAN INSIDE CEILING ​100 MM. Ø PVC VENTILATION PIPE


AIR FLOW DIRECTION

FLUSHED TYPE ​EXTRACTOR VENT ​DIFFUS E R S

INSULATED REFRIGERANT

PIPELINE & RISER INSIDE PVC DUCT

COLD WATER DRAIN PIPE

FROM INDOOR AC UNIT

POWER SUPPLY CABLE

INSIDE PVC CONDUIT PIPE

1981

6' - 6"

3905

12' - 10"

1910

6' - 3"

WEATHERPROOF ISOLATOR SWITCH ​WITH INSULATED POWER LINES INSIDE ​PVC CONDUIT RISER FROM FIRST ​FLOOR ACU UNIT

NOTES:

GENERAL:

1.ALL WORKS TO BE CONSTRUCTED BY A

SANITARY CONSTRUCTOR LICENSED BY

THE WATER AND SEWAGE AUTHORITY OF

TRINIDAD & TOBAGO.

2.ALL WORKS SHALL COMPLY WITH: THE

NATIONAL PLUMBING CODE OF TRINIDAD

& TOBAGO.

3.

THE LICENSED SANITARY CONSTRUCTOR ​SHALL ENSURE THAT WASA'S

REPRESENTATIVE SHALL INSPECT AND ​APPROVE ALL STAGES OF THE WORKS AND ​SHALL OBTAIN FINAL APPROVAL.

4.ALL GRAVITY PIPES AND FITTINGS SHALL

MEET THE REQUIREMENTS AND COMPLIANT

WITH ASTM 2665

5.ALL PRESSURE PIPES :AND FITTINGS

SHALL BE PVC SCHEDULE 40.

POTABLE WATER SYSTEM :

1.ALL MATERIALS SHALL CONFORM WITH

THE FOLLOWING BRITISH OR EQUIVALENT

AMERICAN STANDARDS CODES.

(A) BS EN 1452-1: 2000 GENERAL

(B) BS EN 1452-2: 2000 PIPES

(C) BS EN 1452-3: 2000 FITTINGS

2.ALL FIXTURES ARE TO BE PROVIDED

WITH ANGLE GATE VALVES


3.THE OVERFLOW TO ALL WATER CLOSETS

TO BE PIPED TO THE OUTSIDE OF THE

BUILDING.

4.EACH SUPPLY BRANCHES SHALL HAVE AN

ISOLATING GATE VALVES.


5.ALL PIPES ARE TO BE PRESSURE TESTED

AND CAPPED OFF IN SEGMENTS BEFORE

COVER UP AND FINAL COMMISIONING.

DRAIN, WASTE & VENT SYSTEM

ALL PRESSURE PIPES AND FITTINGS

1.

SHALL BE PVC SCHEDULE 40.

2.ALL PIPES UNDER BUILDING OR UNDER

CONCRETE SLAB TO BE SCHEDULE-80

PVC PIPES.

3.GRADES TO PIPE AS FOLLOWS:

(A)100∅ PIPE = 4 : 300

(B)150∅ PIPE = 6 : 300

4.CLEANOUT TO BE PLACED EVERY

1500MM APART.

DRAWING ISSUE:

PROMOTIONAL ​INFORMATION

RE VISION:

ISSUE: REVISION:

DATE

MM:DD:YY

DRAWING TITLE:

MECHANICAL FLOOR PLANS

DESIGNED ​DRAWN ​CHECKED

DATE

SCALE


PROJECT:

APR / RFMaraya ​LITEDARCH

D Bro ok s

Issue Date

1 : 50

20 No. TOWNHOUSES

DRWG.#

M-01

T.Q. REF.#

EverGreen by Andoma

Lot Nos. 1 & 2a,

Warren Road, Chaguanas.

CLIENT:

APR ASSOCIATES LIMITED

32 AGOSTINI STREET, ST. JOSEPH

APR ASSOCIATES LIMITED ​E P MANAGERS.

NGINEERS &ROJECT

#32 Agostini Street,

St. Joseph,

Trinidad West Indies. ​Phone:(868) 663-5171

Fax: (868) 662-1667

TOP OF PARAPET WALL ​9775

75MM. Ø FULLBORRE ROOF DRAIN

8' - 9"

2671

TOP OF ROOF DECK ​710475MM.Ø PVC DOWNSPOUT BEHIND

MASONRY WALL

PROVIDE DRYWALL CLADDINGH

304 ​1' - 0"

ACCU W/ 100 MM. HT. ​CONCRETE PLINTH

AC CLG#04 OUTLINE

ACCU W/ 100 MM. HT. ​CONCRETE PLINTH

BLOCKWALL RAILING HEIGHT

RECOMMENDED CEILING LEVEL

AC CLG#03 OUTLINE

1050

3' - 5"

10' - 8"

3239

20 MM. Ø PVC CONDENSATE DRAIN ​TAPPED TO DOWNSPOUT

FIRST FLOOR LEVEL ​3865

9' - 0"

2749

DIFFUSER FOR EXTRACTOR FAN W/

100 MM.Ø PVC VENT PIPE INSIDE CEILING

11' - 7"

3539

RECOMMENDED CEILING LEVEL

20 MM. Ø PVC CONDENSATE DRAINS ​EMBEDDED IN CONCRETE WALL AND

DRAIN TO GREY WATER PIPE AT

PARKING LEVEL

9' - 5"

2867

Ground Floor Level

326

Parking Level

26

100 MM. Ø PVC RAIN WATER DISCHARGE PIPE

100 MM. Ø SCHED-40 PVC SEWER/

WASTE SOIL PIPE

INVERT LEVEL = - 380 MM FROM PARKING LEVEL

50 MM. Ø PVC GREY WATER PIPE ​TAPPED TO MAIN WASTE/SOIL PIPE ​(1.5% SLOPE) UNDER RC SLAB

CO

0' - 11"

285

20 MM.Ø PVC CONDENSATE DRAIN PIPE ​TAPPED TO PVC GREY WATER PIPE AT ​BELOW GRADE

1

M−02

MECHANICAL ELEVATIONS

1 : 50

FRONT ELEVATION

TOP OF PARAPET WALL ​9775

6759 ​22' - 2"

100 MM. Ø PVC ROOF VENT CAP

75 MM. Ø FULLBORRE ROOF DRAIN

TOP OF ROOF DECK

7104

75MM. Ø PVC RAIN LEADER FROM ROOF DECK ​BEHIND MASONRY WALL, PROVIDE DRYWALL ​CLADDING - SEE DETAIL

ACCU W/ 100 MM. HT. ​CONCRETE PLINTH

BLOCKWALL RAILING HT.

EXTRACTOR FAN GRILLE W/ ​PVC VENT PIPE INSIDE CEILING

20 MM.Ø PVC CONDENSATE DRAIN EMBEDDED IN WALL ​RECOMMENDED CEILING LEVEL

AC CLG#02 OUTLINE

669

100 MM. Ø PVC VENT THRU ROOF PIPE

2671

8' - 9"

21' - 8"

9' - 0"

2743

3

M-03M-01

6603

FIRST FLOOR LEVEL

3865

EXTRACTOR FAN GRILLE W/

PVC VENT PIPE INSIDE CEILING


75MM. Ø PVC RAIN KLEADER/ DOWNAPOUT

SCHEDULE 40

9' - 5"

2867

20MM.Ø PVC CONDENSATE DRAINS ​DISCHARGED TO UTILITY SINK DRAIN ​AT LAUNDRY ROOM

Ground Floor Level

Parking Level

326

150 ​26

75MMØ PVC DWV PIPE TO SERVICE ​BOX DRAINS AT REAR OF PROPERTY

71

20 MM.Ø CONDENSATE DRAINS FROM

AC CLG#02 TAPPED TO WASH BASIN DRAIN ​IN MASTER'S BATH

2286

7' - 6"

3239

10' - 8"

785

RECOMMENDED CEIL;ING LEVEL

AC CLG# 01 OUTLINE

672

100MM. Ø PVC WASTE STACK/ RISER PIPE-

SCHEDULE 40 (BEHIND CHB WALL) - ​PROVIDE DRYWALL CLADDING

2411

7' - 11"

3539

11' - 7"

ACCU #01 OUTDOOR UNIT

100 MM.Ø SCHED-40 PVC WASTE/SOIL PIPE = SLOPE 1.25%

CO

50 MM. Ø SCHED-40 PVC LOOP VENT

176

100MM.Ø PVC WASTE /SOIL PIPE ​FROM POWDER ROOM & LAUNDRY

IL OF 100 MM. Ø SEWER /WASTE SOIL PIPE = ​- 176MM FROM PARKING LEVEL

REAR ELEVATION

100 ​0' - 4"

100 MM.Ø S-40 PVC WASTE STACK/ VTR

50 MM.Ø PVC LOOP VENT

103 99

0' - 4"0' - 4"

150 MM. THK MASONRY WALL

150

0' - 6"

300 ​1' - 0"

50X50 MM.X 1.20 MM METAL STUDS

75MMØ PVC DOWNSPOUT/

RAIN LEADER W/ PVC STRAPS @

1000 MM.O.C.


12.50 MM. MOISTURE RESISTANT

GYPSUM BOARDS ON

METAL STUDS FRAME

100 MMØ PVC WYE + CO

50X50 MM.X 1.20 MM METAL STUDS

12.50 MM. CEMENT BOARDS ON ​METAL STUDS FRAME

200

0' - 8"

300 ​1' - 0"

100 MMØ SCHED 40- PVC WASTE PIPE ​WYE + CLEANOUT

3

M−02

GB CLADDING DETAILS

1 : 10

2

M−02

CB CLADDING DETAILS

1 : 10

NOTES:

GENERAL:

1.ALL WORKS TO BE CONSTRUCTED BY A

SANITARY CONSTRUCTOR LICENSED BY

THE WATER AND SEWAGE AUTHORITY OF

TRINIDAD & TOBAGO.

2.ALL WORKS SHALL COMPLY WITH: THE

NATIONAL PLUMBING CODE OF TRINIDAD

& TOBAGO.

3.

THE LICENSED SANITARY CONSTRUCTOR ​SHALL ENSURE THAT WASA'S

REPRESENTATIVE SHALL INSPECT AND ​APPROVE ALL STAGES OF THE WORKS AND ​SHALL OBTAIN FINAL APPROVAL.

4.ALL GRAVITY PIPES AND FITTINGS SHALL

MEET THE REQUIREMENTS AND COMPLIANT

WITH ASTM 2665

5.ALL PRESSURE PIPES :AND FITTINGS

SHALL BE PVC SCHEDULE 40.

POTABLE WATER SYSTEM :

1.ALL MATERIALS SHALL CONFORM WITH

THE FOLLOWING BRITISH OR EQUIVALENT

AMERICAN STANDARDS CODES.

(A) BS EN 1452-1: 2000 GENERAL

(B) BS EN 1452-2: 2000 PIPES

(C) BS EN 1452-3: 2000 FITTINGS

2.ALL FIXTURES ARE TO BE PROVIDED

WITH ANGLE GATE VALVES


3.THE OVERFLOW TO ALL WATER CLOSETS

TO BE PIPED TO THE OUTSIDE OF THE

BUILDING.

4.EACH SUPPLY BRANCHES SHALL HAVE AN

ISOLATING GATE VALVES.


5.ALL PIPES ARE TO BE PRESSURE TESTED

AND CAPPED OFF IN SEGMENTS BEFORE

COVER UP AND FINAL COMMISIONING.

DRAIN, WASTE & VENT SYSTEM

ALL PRESSURE PIPES AND FITTINGS

1.

SHALL BE PVC SCHEDULE 40.

2.ALL PIPES UNDER BUILDING OR UNDER

CONCRETE SLAB TO BE SCHEDULE-80

PVC PIPES.

3.GRADES TO PIPE AS FOLLOWS:

(A)100∅ PIPE = 4 : 300

(B)150∅ PIPE = 6 : 300

4.CLEANOUT TO BE PLACED EVERY

1500MM APART.

DRAWING ISSUE:

PROMOTIONAL ​INFORMATION

RE VISION:

ISSUE: REVISION:

DATE

MM:DD:YY

DRAWING TITLE:

ELEVATIONS- AC & ACCU

DESIGNED ​DRAWN ​CHECKED

DATE

SCALE


PROJECT:

APR / RFMaraya ​LITEDARCH

DBrooks

Issue Date

As indicated

20 No. TOWNHOUSES

DRWG.#

M-02

T.Q. REF.#

EverGreen by Andoma

Lot Nos. 1 & 2a,

Warren Road, Chaguanas.

CLIENT:

APR ASSOCIATES LIMITED

32 AGOSTINI STREET, ST. JOSEPH

APR ASSOCIATES LIMITED ​E P MANAGERS.

NGINEERS &ROJECT

#32 Agostini Street,

St. Joseph,

Trinidad West Indies. ​Phone:(868) 663-5171

Fax: (868) 662-1667

203

8"

1050 MM.

3' - 3"

TOP OF ROOF DECK ​7104

103 MM. THICK CONCRETE PLINTH ​FOR AC CONDENSING UNITS

ACCU #03

PROVIDE PVC TRUNK COVER FOR INSULATED ​REFRIGERANT LINES MOUNTED INSIDE CEILING ​AND UNDERSIDE OF ROOF DECK CONCRETE SLAB

3239

10' - 8"

SLIDING SASH uPVC WINDOWS ​W/ GREEN FLOAT GLASS

FIRST FLOOR LEVEL ​3865

ISOLATOR SWITCH

POWER SUPPLY TO AIR CONDITIONING UNIT ​IN PVC CONDUIT PIPE EMBEDDED IN ​MASONRY WALL

ENTERTAINMENT AREA

250 X 600 MM RC FLOOR BEAM

103

4"

ACU CLG #03

INSULATED REFRIGERANT PIPE LINES

FROM AC CLG UNIT TO OUTDOOR ACCU


CEILING LEVEL

10 MM. GYPSUM CEILING BOARDS

ON METAL FURING @ 400 MM.O.C.

4,500 BTU CEILING TYPE

SPLIT AIR CONDITIONER

20MM.Ø PVC CONDENSATE DRAINS

INSIDE MASONRY WALL- TAPPED /

DRAIN AT NEARBY DOWNSPOUT

2264

7' - 5"

2629

8' - 8"

BEDROOM 03

KITCHEN

FIRST FLOOR & ROOF DECK LEVEL ​AIRCON DETAILS @ ACCU#03

NOTES:

MAIN VENT PIPE ​VENT THRU ROOF ​(V TR)

FIRST FLOOR LEVEL ​3865

1% SLOPE FOR WASTE PIPE FROM TOILET

S @ FIRST FLOOR

CO

10 MM. GYPSUM CEILING BOARDS ON ​METAL FURING @ 400 MM.O.C.

FLOOR TO FLOOR HEIGHT = 11' 2"

AC CLG#01

2743

ACU MOUNTING HEIGHT

20,800 BTU (MIN.) CEILING TYPE

SPLIT AIR CONDITIONER

INSULATED REFRIGERANT PIPE LINES

INSIDE PVC TRUNKING ( SURFACE MOUNTED)

FROM ACCU TO CEILING TYPE ACU

25MM.Ø PVC CONDENSATE DRAINS

INSIDE MASONRY WALL- 100 MM BESIDE

DOOR FRAME- DRAIN AT UTILITY SINK

AT LAUNDRY ROOM

9' - 0"

2300 MM.

7' - 7"

LIVING ROOM

915 MM.

3'-0"

ISOLATOR SWITCH

REINFORCED 150 MM. THICK MASONRY WALL WING


PROVIDE PVC TRUNK CIOVER FOR INSULATED

REFRIGERANT LINES MOUNTED INSIDE CEILING

AND UNDERSIDE OF ROOF DECK CONCRETE SLAB

ACU & ACCU POWER SUPPLY CABLE INSIDE ​19MM.Ø PVC CONDUIT PIPE EMBEDDED IN ​MASONRY WING WALL

100 MM.Ø SCHEDULE 40 POVC WASTE STACK ​& VENT THRU ROOF (VTR)- (SEE PLUMBING ​DRAWINGS)

GENERAL:

1.ALL WORKS TO BE CONSTRUCTED BY A

SANITARY CONSTRUCTOR LICENSED BY

THE WATER AND SEWAGE AUTHORITY OF

TRINIDAD & TOBAGO.

2.ALL WORKS SHALL COMPLY WITH: THE

NATIONAL PLUMBING CODE OF TRINIDAD

& TOBAGO.

3.

THE LICENSED SANITARY CONSTRUCTOR ​SHALL ENSURE THAT WASA'S

REPRESENTATIVE SHALL INSPECT AND ​APPROVE ALL STAGES OF THE WORKS AND ​SHALL OBTAIN FINAL APPROVAL.

4.ALL GRAVITY PIPES AND FITTINGS SHALL

MEET THE REQUIREMENTS AND COMPLIANT

WITH ASTM 2665

5.ALL PRESSURE PIPES :AND FITTINGS

SHALL BE PVC SCHEDULE 40.

POTABLE WATER SYSTEM :

1.ALL MATERIALS SHALL CONFORM WITH

THE FOLLOWING BRITISH OR EQUIVALENT

AMERICAN STANDARDS CODES.

(A) BS EN 1452-1: 2000 GENERAL

(B) BS EN 1452-2: 2000 PIPES

(C) BS EN 1452-3: 2000 FITTINGS

2.ALL FIXTURES ARE TO BE PROVIDED

WITH ANGLE GATE VALVES


3.THE OVERFLOW TO ALL WATER CLOSETS

TO BE PIPED TO THE OUTSIDE OF THE

BUILDING.

4.EACH SUPPLY BRANCHES SHALL HAVE AN

ISOLATING GATE VALVES.


5.ALL PIPES ARE TO BE PRESSURE TESTED

AND CAPPED OFF IN SEGMENTS BEFORE

COVER UP AND FINAL COMMISIONING.

DRAIN, WASTE & VENT SYSTEM

ALL PRESSURE PIPES AND FITTINGS

1.

SHALL BE PVC SCHEDULE 40.

2.ALL PIPES UNDER BUILDING OR UNDER

CONCRETE SLAB TO BE SCHEDULE-80

PVC PIPES.

3.GRADES TO PIPE AS FOLLOWS:

(A)100∅ PIPE = 4 : 300

(B)150∅ PIPE = 6 : 300

4.CLEANOUT TO BE PLACED EVERY

1500MM APART.

OUTLINE OF DOOR FRAME

Ground Floor Level- Block

326

ACCU#01

INSULATED REFRIGERANT PIPE LINES

INSIDE PVC TRUNKING ( SURFACE MOUNTESD) ​FROM ACCU TO CEILING TYPE ACU

103 MM. THICK CONCRETE PLINTH

FOR AC CONDENSING UNITS

100

Parking Level

0' - 4"

GROUND FLOOR

AIRCON DETAILS @ ACCU#01

700


2' - 4"

DRAWING ISSUE:

PROMOTIONAL ​INFORMATION

RE VISION:

ISSUE: REVISION:

DATE

MM:DD:YY

DRAWING TITLE:

AIRCON DETAILS

DESIGNED ​DRAWN ​CHECKED

DATE

SCALE


PROJECT:

APR / RFMaraya ​LITEDARCH

DBrooks

Issue Date

1 : 20

20 No. TOWNHOUSES

DRWG.#

M-03

T.Q. REF.#

EverGreen by Andoma

Lot Nos. 1 & 2a,

Warren Road, Chaguanas.

CLIENT:

APR ASSOCIATES LIMITED

32 AGOSTINI STREET, ST. JOSEPH

APR ASSOCIATES LIMITED ​E P MANAGERS.

NGINEERS &ROJECT

#32 Agostini Street,

St. Joseph,

Trinidad West Indies. ​Phone:(868) 663-5171

Fax: (868) 662-1667