NOTES:

1. ALL DIMENSIONS ARE IN METRIC


2. FIXED DATUM/ REFERENCE FOR ​INVERT LEVELS IS THE PARKING ​LEVEL.

EXISTING EARTHEN ROAD SIDE DRAIN

REINFORCED CONCRETE DRAIN ​CULVERTS

GARBAGE

HOLDING SHED

450 MM WIDE CONCRETE BOX DRAIN W/ GRATINGS

2575 ​8' - 5"

ACCU

PP

ACCU

PP

ACCU

PP

ACCU

PP

450 MM WIDE CONCRETE BOX DRAIN W/ GRATINGS

ACCU

ACCU

PP

PP

ACCU

PP

ACCU

PP

PP

2919 ​9' - 7"

2919 ​9' - 7"

2919 ​9' - 7"

2919 ​9' - 7"

1294 ​4' - 3"

450 MM WIDE CONCRETE BOX DRAIN W/ GRATINGS

1334

4' - 5"

DR A IN

DR A IN

DR A IN

DR A IN

DRAIN

DR A IN

1333

4' - 4"

ACCU

DR A IN

WATER TANK FARM

DRAIN

6043

19' - 10"

PP

DR A IN

EXISTING WASA 100 MM. Ø PVC POTABLE WATER MAINS ALONG WARREN ROAD

PROPOSED ___K

T&TEC SERVICE POLE

PROPOSED REINFORCED CONCRETE

DRAIANGE CROSSING UNDER NEW DRIVEWAY

INVERT LEVEL = -500 MM.

EV & LV ​PULLBOX

44 NNRRSS.. XX 110000MMMM..ØØ PPVVCC DDUUCCTTSS FFOORR LLVV PPOOWWEERR

REINFORCED CONCRETE DRAIN ​CULVERTS UNDER DRIVEWAY

GU A RD ​B OOTH

ON-SITE WASTE WATER ​TREATMENT SYSTEM

2NRS.X 38MM.Ø PVC ​DUCTS FOR TEL&CATV

PP

22 NNRRSS.. XX 110000MMMM..ØØ PPVVCC DDUUCCTTSS FFOORR CCAATTVV && TTEELL

MANHOLE # 02

1 NR X 50 MM.Ø PVC DUCT FOR LV POWER

TEL ​CATV

2NRS.X 38MM.Ø PVC ​DUCTS FOR TEL&CATV

2 NRS. X 50MM.Ø PVC DUCTS FOR CATV & TEL

PP

EV & LV ​PULLBOX

SITE LIGHTING

& POWER PANEL

2NRS. X 38 MM.Ø PVC ​DUCTS FOR TEL & CATV

EXISTING EARTHEN ROAD SIDE DRAIN

44 NNRRSS.. XX 110000MMMM..ØØ PPVVCC DDUUCCTTSS FFOORR LLVV PPOOWWEERR

33 NNRRSS.. XX 110000MMMM..ØØ PPVVCC DDUUCCTTSS FFOORR CCAATTVV && TTEELL

ON-SITE WASTE WATER ​TREATMENT SYSTEM

PP

50MM.Ø PVC POWER SUPPLY PIPE

CATV ​TEL

2NRS. X 38 MM.Ø PVC ​DUCTS FOR TEL & CATV

1 NR X 50 MM.Ø PVC DUCT FOR LV POWER

PP

1 NR. X 100MM. Ø LV DUCT ​RISING ON POLE

150 MM. Ø CUSTOMER ​SERVICE POLE

2 NRS. X 50MM.Ø ELV ​DUCTS RISING ON POLE

LV & EV ​PULLBOX

SPLITTER PANEL ​W/ METER BANK

TEL

CATV

CATV & TEL DISTRIBUTION BOXES


150 MM. THK.RC SUPPORT WALL

X 2100 MM. HT.

2840 ​9' - 4"

ACCU

1 NR X 50 MM.Ø PVC DUCT FOR LV POWER

TEL ​CATV

TEL ​CATV

2NRS.X 38MM.Ø PVC ​DUCTS FOR TEL&CATV

2NRS. X 100MM.Ø PVC DUCTS FOR LV POWER

1 NR X 50 MM.Ø PVC DUCT FOR LV POWER

2NRS.X 38MM.Ø PVC ​DUCTS FOR TEL&CATV

2 NRS. X 50MM.Ø PVC DUCTS FOR CATV & TEL

CATV ​TEL

2NRS. X 100MM.Ø PVC DUCTS FOR LV POWER

2NRS. X 38 MM.Ø PVC ​DUCTS FOR TEL & CATV

1 NR X 50 MM.Ø PVC DUCT FOR LV POWER

PP

ACCU

2 NRS. X 50MM.Ø PVC DUCTS FOR CATV & TEL

2NRS. X 38 MM.Ø PVC ​DUCTS FOR TEL & CATV

CATV ​TEL

1 NR X 50 MM.Ø PVC DUCT FOR LV POWER

PP

ACCU

TEL ​CATV

CATV ​TEL

1 NR X 50 MM.Ø PVC DUCT FOR LV POWER

1 NR X 50 MM.Ø PVC DUCT FOR LV POWER

TEL ​CATV

2NRS.X 38MM.Ø PVC ​DUCTS FOR TEL&CATV

2NRS. X 100MM.Ø PVC DUCTS FOR LV POWER

2 NRS. X 50MM.Ø PVC DUCTS FOR CATV & TEL

2NRS. X 38 MM.Ø PVC

DUCTS FOR TEL & CATV

EV & LV ​PULLBOX

1200

1200

1 NR X 50 MM.Ø PVC DUCT FOR LV POWER

TEL ​CATV

2NRS.X 38MM.Ø PVC ​DUCTS FOR TEL&CATV

600 MM.

INVERT LEVEL = - 810 MM.

2NRS. X 38 MM.Ø PVC ​DUCTS FOR TEL & CATV

1 NR X 50 MM.Ø PVC DUCT FOR LV POWER

CATV ​TEL

PP

ACCU

1 NR X 50 MM.Ø PVC DUCT FOR LV POWER

EV & LV ​PULLBOX

2NRS. X 38 MM.Ø PVC ​DUCTS FOR TEL & CATV

CATV ​TEL

PP

ACCU

2NRS. X 38 MM.Ø PVC ​DUCTS FOR TEL & CATV

1 NR X 50 MM.Ø PVC DUCT FOR LV POWER

PP

ACCU

TEL ​CATV

CATV ​TEL

1 NR X 50 MM.Ø PVC DUCT FOR LV POWER

2NRS. X 38 MM.Ø PVC ​DUCTS FOR TEL & CATV

2 NRS. X 50MM.Ø PVC DUCTS FOR CATV & TEL

TEL ​CATV

30937 ​101' - 6"

1 NR X 50 MM.Ø PVC DUCT FOR LV POWER

2NRS. X 38 MM.Ø PVC ​DUCTS FOR TEL & CATV

TEL ​CATV

1NR. X 100MM.Ø PVC DUCTS FOR LV POWER

1 NR X 50 MM.Ø PVC DUCT FOR LV POWER

2NRS. X 38 MM.Ø PVC ​DUCTS FOR TEL & CATV

2 NRS. X 50MM.Ø PVC DUCTS FOR CATV & TEL

INVERT LEVEL = -250 MM.

TEL ​CATV

2 NRS. X 50MM.Ø PVC DUCTS FOR CATV & TEL

1NR. X 100MM.Ø PVC DUCTS FOR LV POWER

2NRS. X 38 MM.Ø PVC ​DUCTS FOR TEL & CATV

2NRS. X 38 MM.Ø PVC ​DUCTS FOR TEL & CATV

CATV ​TEL

CATV ​TEL

1 NR X 50 MM.Ø PVC DUCT FOR LV POWER

1 NR X 50 MM.Ø PVC DUCT FOR LV POWER

PP

PP

ACCU

ACCU

2NRS. X 38 MM.Ø PVC ​DUCTS FOR TEL & CATV

CATV ​TEL

1 NR X 50 MM.Ø PVC DUCT FOR LV POWER

PP

ACCU

450 MM. WIDE RC BOX DRAIN W/ GRATING

1

E-01

SITE ELECTRICAL DISTRIBUTION PLAN

1 : 150

1 NR X 50 MM.Ø PVC DUCT FOR LV POWER

INVERT LEVEL = -355 MM.

11 NNRR XX 5500 MMMM..ØØ PPVVCC DDUUCCTT FFOORR LLVV PPOOWWEERR

9051 ​29' - 8"

1 NR X 50 MM.Ø PVC DUCT FOR LV POWER

PP

ACCU

1 NR X 25 MM.Ø PVC CONDUIT ​FOR WATER PUMP

INVERT LEVEL = -500 MM.

PUMP ROOM

PP

GAZEBO

7620 ​25' - 0"

SWIMMING POOL

11650

9144

38' - 3"

30' - 0"

11582

38' - 0"

PC

LED

LED

SD


HD

WP

T

GFP23

TWH

LEGEND -ELECTRICAL

1 : 50

32 WATTS LED LIGHT FIXTURE CEILING MOUNTED

PHOTO CELL SWITCH


FIXTURE- WALL MOUNTED19 WATTS LED LIGHT


BATTERY OPERATED SMOKE DETECTOR ​BATTERY OPERATED HEAT DETECTOR

DUPLEX CONVENIENCE GFCI OUTLET- 115 V

WEATHER PROOF DUPLEX COMVENIENCE OUTLET- ​115 VOLTS

SINGLE POLE SWITCH- FLUSHED TYPE

TWO POLE SWITCH- FLUSHED TYPE

TV/CABLE OUTLET


TELEPHONE/LANDLINE OUTLET

POWERLINE CABLE INSIDE 16MM. PVC CONDUIT PIPE

SWITCHLINE CABLE INSIDE 12 MM.Ø PVC CONDUIT PIPE

CIRCUIT HOMERUN

TANKLESS WATER HEATER

DRAWING ISSUE:

PROMOTIONAL ​INFORMATION

RE VISION:

ISSUE: REVISION:

DATE

MM:DD:YY

DRAWING TITLE:

SITE ELECTRICAL DSITRIBUTION ​PLAN

DESIGNED ​DRAWN ​CHECKED

DATE

SCALE


PROJECT:

APR / RFMaraya ​LITEDARCH

D Bro ok s

Issue Date

As indicated

20 No. TOWNHOUSES

DRWG.#

E-01

T.Q. REF.#

EverGreen by Andoma

Lot Nos. 1 & 2a,

Warren Road, Chaguanas.

CLIENT:

APR ASSOCIATES LIMITED

32 AGOSTINI STREET, ST. JOSEPH

APR ASSOCIATES LIMITED ​E P MANAGERS.

NGINEERS &ROJECT

#32 Agostini Street,

St. Joseph,

Trinidad West Indies. ​Phone:(868) 663-5171

Fax: (868) 662-1667

10870

35' - 8"

OPEN SPACE

1524

5' - 0"

6759 ​22' - 2"

PC

WL

LIVING AREA ​GF09

SD

LED

SD

LED

LAUNDRY & STORAGE ​GF11

POWDER ROOM

LED

GF10

STORAGE ​GF07

LED

MAIN STAIRCASE

PANTRY ​GF06

WL

DINING AREA ​GF05

LED

SD

KITCHEN ​GF03

RANGE HOOD

LED TRACKLIGHTS

LED

FOYER ​GF02

WL

WL

PC

LANDSCAPED AREA

ONE STEP ​ENTRY UP

FRONT YARD

LANDSCAPED AREA

1500 MM. WIDE CONCRETE SIDEWALK

5500

18' - 1"

PARKING AREA

1

E−02

GROUND FLOOR−ELECTRICAL PLAN−LO

1 : 50

R

2589 ​8' - 6"

6759 ​22' - 2"

LED

3870 ​12' - 8"

3988

13' - 1"

1831

6' - 0"

WL

TV

LED

LED

2

WL

2

GFL-13

1

UP

234567


MAIN STAIRCASE

8

WL

UP

2W

10973

36' - 0"

4704

15' - 5"

LED

2

LED

LED

899

2' - 11"

2

E−02

FIRST FLOOR −ELECTRICAL PLAN−LO

1 : 50

ROOF LINE

ROOF PLANTERS

LED TRACKLIGHTS

ROOF TOP DINING

LED

GREEN ROOF ENTERTAINMENT AREA

C O R R I D O R

ROOF LINE

sink/ ref

T

LED

LANDING

MAIN STAIRCASE

T

GFP23

LED

ROOF DECK ​LOUNGE AREA

REINFORCED ​CONCRETE ROOF ​DECKING

ROOF LINE

3

E−02

PC

LED

LED

SD

HD

WP

T

GFP23

TWH

ROOF DECK ELECTRICAL PLAN− LO

1 : 50

LEGEND −ELECTRICAL

1 : 50

32 WATTS LED LIGHT FIXTURE CEILING MOUNTED

PHOTO CELL SWITCH


19 WATTS LED LIGHT FIXTURE- WALL MOUNTED


BATTERY OPERATED SMOKE DETECTOR

BATTERY OPERATED HEAT DETECTOR

DUPLEX CONVENIENCE GFCI OUTLET- 115 V

WEATHER PROOF DUPLEX COMVENIENCE OUTLET- ​115 VOLTS

SINGLE POLE SWITCH- FLUSHED TYPE

TWO POLE SWITCH- FLUSHED TYPE

TV/CABLE OUTLET


TELEPHONE/LANDLINE OUTLET

POWERLINE CABLE INSIDE 16MM. PVC CONDUIT PIPE

SWITCHLINE CABLE INSIDE 12 MM.Ø PVC CONDUIT PIPE

CIRCUIT HOMERUN

TANKLESS WATER HEATER

NOTES:

GENERAL:

1.ALL WORKS TO BE CONSTRUCTED BY A

SANITARY CONSTRUCTOR LICENSED BY

THE WATER AND SEWAGE AUTHORITY OF

TRINIDAD & TOBAGO.

2.ALL WORKS SHALL COMPLY WITH: THE

NATIONAL PLUMBING CODE OF TRINIDAD

& TOBAGO.

3.

THE LICENSED SANITARY CONSTRUCTOR ​SHALL ENSURE THAT WASA'S

REPRESENTATIVE SHALL INSPECT AND ​APPROVE ALL STAGES OF THE WORKS AND ​SHALL OBTAIN FINAL APPROVAL.

4.ALL GRAVITY PIPES AND FITTINGS SHALL

MEET THE REQUIREMENTS AND COMPLIANT

WITH ASTM 2665

5.ALL PRESSURE PIPES :AND FITTINGS

SHALL BE PVC SCHEDULE 40.

POTABLE WATER SYSTEM :

1.ALL MATERIALS SHALL CONFORM WITH

THE FOLLOWING BRITISH OR EQUIVALENT

AMERICAN STANDARDS CODES.

(A) BS EN 1452-1: 2000 GENERAL

(B) BS EN 1452-2: 2000 PIPES

(C) BS EN 1452-3: 2000 FITTINGS

2.ALL FIXTURES ARE TO BE PROVIDED

WITH ANGLE GATE VALVES


3.THE OVERFLOW TO ALL WATER CLOSETS

TO BE PIPED TO THE OUTSIDE OF THE

BUILDING.

4.EACH SUPPLY BRANCHES SHALL HAVE AN

ISOLATING GATE VALVES.


5.ALL PIPES ARE TO BE PRESSURE TESTED

AND CAPPED OFF IN SEGMENTS BEFORE

COVER UP AND FINAL COMMISIONING.

DRAIN, WASTE & VENT SYSTEM

ALL PRESSURE PIPES AND FITTINGS

1.

SHALL BE PVC SCHEDULE 40.

2.ALL PIPES UNDER BUILDING OR UNDER

CONCRETE SLAB TO BE SCHEDULE-80

PVC PIPES.

3.GRADES TO PIPE AS FOLLOWS:

(A)100∅ PIPE = 4 : 300

(B)150∅ PIPE = 6 : 300

4.CLEANOUT TO BE PLACED EVERY

1500MM APART.

DRAWING ISSUE:

PROMOTIONAL ​INFORMATION

RE VISION:

ISSUE: REVISION:

DATE

MM:DD:YY

DRAWING TITLE:

LIGHT OUTLETS ELECTRICAL ​FLOOR PLANS

DESIGNED ​DRAWN ​CHECKED

DATE

SCALE


PROJECT:

APR / RFMaraya ​LITEDARCH

D Bro ok s

Issue Date

1 : 50

20 No. TOWNHOUSES

DRWG.#

E-02

T.Q. REF.#

EverGreen by Andoma

Lot Nos. 1 & 2a,

Warren Road, Chaguanas.

CLIENT:

APR ASSOCIATES LIMITED

32 AGOSTINI STREET, ST. JOSEPH

APR ASSOCIATES LIMITED ​E P MANAGERS.

NGINEERS &ROJECT

#32 Agostini Street,

St. Joseph,

Trinidad West Indies. ​Phone:(868) 663-5171

Fax: (868) 662-1667

4056 ​13' - 4"

6759 ​22' - 2"

2703 ​8' - 10"

10870

35' - 8"

OPEN SPACE

600

2' - 0"

IS

T

19MM. Ø PVC CONDUIT PIPE EMBEDDED IN FLOOR

GFP-1

LIVING ROOM

19MM. Ø PVC CONDUIT PIPE EMBEDDED IN FLOOR

12MM. Ø PVC CONDUIT PIPE EMBEDDED IN FLOOR

GFP-15,17

GFP-2 GFP-4,6


GFP- 25, 26

LAUNDRY ROOM

TWH

12MM. Ø PVC CONDUIT PIPE EMBEDDED IN FLOOR

POWDER ROOM


STORAGE

MAIN STAIRCASE

50 MM. Ø MAIN PVC CONDUIT PIPE W/

# __________ MAIN CONDUCTOR WIRES

PA NTRY

12MM. Ø PVC CONDUIT PIPE EMBEDDED IN FLOOR

DINING ROOM

19MM. Ø PVC CONDUIT PIPE EMBEDDED IN FLOOR

GFP-3

KITCHEN

GFP-8,10

GFP-8,10

OVEN

DIS HW A SHER

GFP-5

19MM. Ø PVC CONDUIT PIPE EMBEDDED IN FLOOR

19MM. Ø PVC CONDUIT PIPE EMBEDDED IN WTALL

TEL/CATV

2 NRS. X 38 MM.Ø PVC CONDUIT SERVICE PIPE

LANDSCAPED AREA

ENTRY PORCH

ONE STEP ​ENTRY UP

FRONT YARD

LANDSCAPED AREA

2 NRS. X 100 MM. Ø PVC DUCTS FOR LV POWER LINES


2 NRS. X 50 MM. Ø PVC DUCTS FOR CABLE/DATA/TV LINES

50 MM. Ø MAIN PVC CONDUIT PIPE W/

# __________ MAIN CONDUCTOR WIRES

550 MM.

1500 MM. WIDE CONCRETE SIDEWALK

650 MM.

2011

1041

1062

1981

6' - 7"

3' - 6"3' - 5"

6' - 6"

4775

15' - 8"

3124

733

10' - 3"

2' - 5"

2500 MM. WIDE PARKING BAYS

1

E−03

GROUND FLOOR−ELECTRICAL PLAN −PO

1 : 50

3988

13' - 1"

1831

6' - 0"

4704

15' - 5"

R

2589 ​8' - 6"

GFCI

19 MM. Ø PVC CONDUIT PIPE UNDER SLAB

MASTER’S BATH & CLOSET ​GF16

COMMON BATH ​GF14

TWH

GFCI

GFP27, 28

GFP -7

19 MM. Ø PVC CONDUIT PIPE IN SLAB

BEDROOM−03 ​GF12

19 MM. Ø PVC CONDUIT PIPE IN SLAB

6759 ​22' - 2"

3870 ​12' - 8"

19 MM. Ø PVC CONDUIT PIPE IN SLAB

GFP-12

MASTER’S BEDROOM ​GF17

TV

19 MM. Ø PVC CONDUIT PIPE IN SLAB

GFP-11

H A L L

19 MM. Ø PVC CONDUIT PIPE IN SLAB

1

UP

234567


MAIN STAIRCASE

8

19

18

17

2W

16

15

14

13

UP

12

T

TV

19 MM. Ø PVC CONDUIT PIPE IN SLAB

TV

19 MM. Ø PVC CONDUIT PIPE IN SLAB

BEDROOM−02 ​GF13

19 MM. Ø PVC CONDUIT PIPE IN SLAB

19 MM. Ø PVC CONDUIT PIPE IN SLAB

IS

LOCATION OF RISER CONDUIT ​PIPES FROM POWER PANELBOARD ​@ GROUND FLOOR LEVEL

GFP-19,21

WP

ROOF LINE

ROOF TOP DINING

ROOF PLANTERS

GFP24

T

10973

36' - 0"

GREEN ROOF ENTERTAINMENT AREA

C O R R I D O R

sink/ ref

LANDING

ROOF LINE

MAIN STAIRCASE

T

ROOF DECK ​LOUNGE AREA

GFP-16,18

899

2' - 11"

GFP-20,22

IS

REINFORCED ​CONCRETE ROOF ​DECKING

IS

ROOF LINE

2

E−03

FIRST FLOOR −ELECTRICAL PLAN−PO

1 : 50

3

E−03

ROOF DECK ELECTRICAL PLAN − PO

1 : 50

LEGEND −ELECTRICAL

1 : 50

PC

LED

LED

SD

HD

WP

T

32 WATTS LED LIGHT FIXTURE CEILING MOUNTED

PHOTO CELL SWITCH


19 WATTS LED LIGHT FIXTURE- WALL MOUNTED


BATTERY OPERATED SMOKE DETECTOR

BATTERY OPERATED HEAT DETECTOR

DUPLEX CONVENIENCE GFCI OUTLET- 115 V


WEATHER PROOF DUPLEX COMVENIENCE OUTLET-

115 VOLTS


SINGLE POLE SWITCH- FLUSHED TYPE


TWO POLE SWITCH- FLUSHED TYPE

TV/CABLE OUTLET


TELEPHONE/LANDLINE OUTLET

POWERLINE CABLE INSIDE 16MM. PVC CONDUIT PIPE

SWITCHLINE CABLE INSIDE 12 MM.Ø PVC CONDUIT PIPE

CIRCUIT HOMERUN

GFP23

TWH

TANKLESS WATER HEATER

NOTES:

GENERAL:

1.ALL WORKS TO BE CONSTRUCTED BY A

SANITARY CONSTRUCTOR LICENSED BY

THE WATER AND SEWAGE AUTHORITY OF

TRINIDAD & TOBAGO.

2.ALL WORKS SHALL COMPLY WITH: THE

NATIONAL PLUMBING CODE OF TRINIDAD

& TOBAGO.

3.

THE LICENSED SANITARY CONSTRUCTOR ​SHALL ENSURE THAT WASA'S

REPRESENTATIVE SHALL INSPECT AND ​APPROVE ALL STAGES OF THE WORKS AND ​SHALL OBTAIN FINAL APPROVAL.

4.ALL GRAVITY PIPES AND FITTINGS SHALL

MEET THE REQUIREMENTS AND COMPLIANT

WITH ASTM 2665

5.ALL PRESSURE PIPES :AND FITTINGS

SHALL BE PVC SCHEDULE 40.

POTABLE WATER SYSTEM :

1.ALL MATERIALS SHALL CONFORM WITH

THE FOLLOWING BRITISH OR EQUIVALENT

AMERICAN STANDARDS CODES.

(A) BS EN 1452-1: 2000 GENERAL

(B) BS EN 1452-2: 2000 PIPES

(C) BS EN 1452-3: 2000 FITTINGS

2.ALL FIXTURES ARE TO BE PROVIDED

WITH ANGLE GATE VALVES


3.THE OVERFLOW TO ALL WATER CLOSETS

TO BE PIPED TO THE OUTSIDE OF THE

BUILDING.

4.EACH SUPPLY BRANCHES SHALL HAVE AN

ISOLATING GATE VALVES.


5.ALL PIPES ARE TO BE PRESSURE TESTED

AND CAPPED OFF IN SEGMENTS BEFORE

COVER UP AND FINAL COMMISIONING.

DRAIN, WASTE & VENT SYSTEM

ALL PRESSURE PIPES AND FITTINGS

1.

SHALL BE PVC SCHEDULE 40.

2.ALL PIPES UNDER BUILDING OR UNDER

CONCRETE SLAB TO BE SCHEDULE-80

PVC PIPES.

3.GRADES TO PIPE AS FOLLOWS:

(A)100∅ PIPE = 4 : 300

(B)150∅ PIPE = 6 : 300

4.CLEANOUT TO BE PLACED EVERY

1500MM APART.

DRAWING ISSUE:

PROMOTIONAL ​INFORMATION

RE VISION:

ISSUE: REVISION:

DATE

MM:DD:YY

DRAWING TITLE:

POWER OUTLETS- ELECTRICAL ​FLOOR PLANS

DESIGNED ​DRAWN ​CHECKED

DATE

SCALE


PROJECT:

APR / RFMaraya ​LITEDARCH

DBrooks

Issue Date

1 : 50

20 No. TOWNHOUSES

DRWG.#

E-03

T.Q. REF.#

EverGreen by Andoma

Lot Nos. 1 & 2a,

Warren Road, Chaguanas.

CLIENT:

APR ASSOCIATES LIMITED

32 AGOSTINI STREET, ST. JOSEPH

APR ASSOCIATES LIMITED ​E P MANAGERS.

NGINEERS &ROJECT

#32 Agostini Street,

St. Joseph,

Trinidad West Indies. ​Phone:(868) 663-5171

Fax: (868) 662-1667